Instructions for Using the COMDUMP Utility
COMDUMP Checklist
- Command format: comdump 1 (or 2)
comdump 3 (or 4) 9600 IRQ#
- Data must not scroll when
screen is not touched
If data scrolls when screen is not touched:
- Bezel is clamped on screen or
- screen is damaged or
- cable is shorted
- Data must scroll when screen
is touched
If data does not scroll on touch:
- Try another COM port if possible
- Try disconnecting the monitor's power cord briefly, then reconnect and try comdump
- To prove that the COM port is OK: connect a serial mouse and move it. If data scrolls, COM port is good
- Hshk indication should be
DSR CTS
If data is OK but handshake is not, try disabling handshaking
- Confirm [55] [54] in data
- If no 55 54 in data:
- an older Elo controller is being used or
- a current Elo controller is set to emulate an older controller or
- a non-Elo controller is being used or
- the controller is malfunctioning or
- the COM port's settings are incorrect: 9600 baud, no parity, 1 stop bit